QUICK REFERENCE GUIDE
96%TWO STAGE MULTI-POSITION RESIDENTAL
GAS FURNACES (33” TALL)
NOTES:
This document does not replace the installation instructions, which must be referred to for
detailed information.
1. If the furnace is equipped with NOx screens and is to be
used with LP (propane) gas, the screens must be removed
prior to start-up.
7. To measure total static pressure, add supply duct pressure
to the return duct pressure, add pressure drop across the ‘A’
coil, and add pressure drop across the filter. Ignore negative
signs on the readings.
SUPPLY END
23.8”
RETURN END
2” Diameter
Vent Connection
Outlet
.56”
2. Drip leg in the gas line must be installed.
3”
8. Inlet gas pressure should be 7” w.c. for natural gas and 11”
w.c. for propane. Nominal manifold gas pressure is 3.5” w.c.
for natural gas and 10” w.c. for propane at max. input.
3. The furnace controls require correct polarity on the power
supply and a proper ground.
DURING INSTALLATION,
DOORS MUST REMAIN ON
FURNACE WHEN MOVING
OR LIFTING.
4. Y & G must be connected to the control board for cooling
operation.
B
Combustion
Air Inlet
9. For downflow application the vent blower must be rotated 90
left or right as shown.
B
5. External filters are required on all configurations.
Clips can be flipped
into the up position
for coil cabinet or
plenum attachment
6. Electrical or gas entry is available on both casing sides.
.56”
.56”
24.25”
Airflow CFM (Bottom Return without Filters)
20”
Minimum Wire
Size awg @ 75'
One-Way
Maximum
Over Current
Protection
†
Models
0.5" ESP (Nominal)
Combustion Air Inlet
Combustion Air Inlet
*D-A**
600
*C-A**
690
*B-A**
1000
1000
1175
1160
1605
1595
*A-B**
1305
1290
1670
1655
2215
2180
TM9V060B12MP11
TM9V080B12MP11
TM9V080C16MP11
TM9V100C16MP11
TM9V100C20MP11
TM9V120D20MP11
14
14
14
14
12
12
15
15
15
15
20
20
Condensate Drain
(Downflow)
Gas Pipe
Entry
Condensate Drain
(Downflow)
600
680
A-COIL
Vent Connection
Outlet
850
905
Electrical
Entry
Vent Connection
Outlet
870
910
Condensate
Drain
960
1155
1160
23”
960
Thermostat
Wiring
3
Input
Rate
Time For 1 ft Natural Gas
Total Unit Air Temp. Rise Air Temp. Rise
Amps
Optional Return Air
Cutout (Either side)
14”
3
Models
(1030 Btu/Ft ) Seconds
Max Input °F
Min Input °F
Max
Min
(On Max. Rate)
1”
TM9V060B12MP11
TM9V080B12MP11
TM9V080C16MP11
TM9V100C16MP11
TM9V100C20MP11
TM9V120D20MP11
60,000
80,000
80,000
21,000
28,000
28,000
9
35 - 65
35 - 65
35 - 65
35 - 65
35 - 65
35 - 65
35 - 65
30 - 60
35 - 65
30 - 60
35 - 65
35 - 65
62
46
46
37
37
31
33”
9
28.5”
29.5”
1.5”
12
12
14
14
100,000 35,000
100,000 35,000
120,000 42,000
RIGHT SIDE
LEFT SIDE
Follow all national and local codes and standards in addition to this document.
The installation must comply with regulations of the serving gas supplier, local building,
heating, plumbing, and other codes. In absence of local codes, the installation must comply
with national codes and all authorities having jurisdiction.
†
Other airflows are available. see Tech Guide for all CFM options.
* Cool Tap.
A
FRONT
** Adjustment Tap.
LED INDICATOR
CLEARANCES
DIMENSIONS
Slow Green Flash - Normal operation in standby mode.
Slow Amber Flash - Normal operation with call for cooling.
Two Amber Flashes - Normal operation with call for heat.
Application
Top
Upflow
Downflow
Horizontal
Cabinet Size
A (in)
17-1/2"
21"
B (in)
1"
0"
0"
0"
0"
0"
0"
0"
0"
0"
0"
All 'B' Cabinet Furnaces
All 'C' Cabinet Furnaces
All 'D' Cabinet Furnaces
16-3/8"
19-7/8"
23-3/8"
Vent
0"
Three Amber Flashes - Normal operation, burner is on at end of
thermostat cycle.
Rear
0"
24-1/2"
Side
1"
0"
Six Amber Flashes - Normal operation with call for heat pump
heating.
Front*
1
Any Red Flash - Fault condition. NOTE: 4 or 5 flashes may indi-
cate a blown fuse on the circuit board.
Floor
Closet
Combustible
Combustible
Yes
Combustible
Yes
No
Yes
No
Line Contact
Yes
Subject to change without notice. Printed in U.S.A.
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.
438336-URG-A-0209
Supersedes: Nothing
1. For combustible floors only when used with special
sub-base.
*438336*
* 24" clearance in front and 18" on side recommended for
service access.
Johnson Controls Unitary Products
5005 York Drive
All furnaces approved for alcove and attic installation.
Norman, OK 73069
|